Completion Acceptance ​

During phase spacing analysis, the calculated result data is empty. ​

You can adjust the clustering threshold parameter according to the line voltage level. The lower the voltage level, the smaller the clustering threshold should be.

In the generated tower ledger, the tower base, tower top, and tower height values are empty. ​

This may be because classification has not been performed. You need to perform clipping and classification first, and then export the tower ledger.

During sag analysis, the message "Please select at least one line file" appears. ​

You need to add the shp vector file of the conductor, shield wire, or jumper wire before performing sag analysis.

During sag analysis, the message "The option to adjust sag according to the point cloud does not support analyzing simulated data" appears. ​

During sag analysis, if "Adjust Sag According to Point Cloud" is checked, you can only add shp vector line files, not LiSim simulation files.

During sag analysis, the message "The power line file format is incorrect" appears. ​

You may have selected the wrong vector line file, for example, selecting the shp vector file of a shield wire or jumper wire for a conductor.

During jumper wire electrical clearance analysis, the message "The shp file is empty. Please set it." appears. ​

"Based on the shp File" is checked, but no shp file has been added.

The report generated by jumper wire electrical clearance analysis contains no images. ​

Check whether the tower marker points are placed on the towers.