Substation Inspection
After importing an osgb oblique model, it does not overlap with the point cloud.
When using DJI Terra for oblique modeling, the coordinate system was not set to a UTM projected coordinate system and WGS 84 was used by default. Set the correct coordinate system and remodel.
Failed to import the substation ledger file.
Check whether the component point names and point IDs in the ledger file are empty, or whether any duplicates exist.
When marking component points, the message "The component point is not within the licensed area. Please select again." appears.
Check whether the coordinate system in Project Configuration is correct.
Check whether the range of the point cloud data is consistent with the area range of the license. You can ask GreenValley staff to check the area range of the license.
The green dots of the marked component points suddenly disappear.
Check whether the component point layer is set to be displayed.
Check whether the "Used for Trajectory Generation" option is checked in the component point list.
When using the copy function, the message "No component point is selected" appears.
Before using the copy function, first use the "Select" tool to select the component points you want to copy.
Which formats of 3D Gaussian models can the software open?
Single files in *.ply and *.lisplat format are supported. For LOD data, the *.xml file is opened by default.