The message "Tower info is not enough. Cannot generate trajectory" appears when generating a fine inspection trajectory for towers.
Only one tower was marked. At least two towers need to be marked.
The message "The component point is not within the licensed area. Please select again." appears when marking component points.
Check whether the coordinate system in Project Configuration is correct.
Check whether the range of the point cloud data is consistent with the area range of the license. You can ask GreenValley staff to check the area range of the license.
When renaming, the message "The number of photos does not match the number of waypoints" appears.
Check whether photos are missing or redundant. Make sure the number of photos matches the number of waypoints.
No photo-taking waypoints are generated when a trajectory is generated automatically.
Check whether the component point numbers have turned into hyphens. If so, it means the inspection configuration information is missing or has been modified and cannot match the current trajectory, and the component points need to be re-marked.
After adding a new tower type and manually marking component points, generating the tower type image reports "Failed to generate the component point configuration file".
Check whether the conductor, tower, shield wire, insulator, and jumper wire have been classified.
At least two towers should be marked in the tower list.
The C drive has no write permission. Right-click the properties of the software shortcut and, on the Compatibility page, check "Run this program as an administrator".
When identifying component points by deep learning, the message "Failed to read the output file" appears.
Check whether the discrete graphics card is an NVIDIA card. This function cannot be used with an AMD graphics card.
Check whether the discrete graphics card driver version is correct. The driver version should be one released in October 2025 or later.