Measure Protect Angle ​

Summary ​

This function is used to measure the protection angle. The protection angle is the angle between the shield wire cross arm to the first wire cross arm and the vertical direction. The tower needs to be classified before using this function. Results as shown below. It is mainly used to measure the bending degree of straight steel such as tower legs and tower body.

Usage ​

Click Measurement > Protect Angle

protect angle

Steps ​

After the protection angle measurement tool is enabled, select the end of the shield wire cross arm and the end of the wire cross arm in turn, and then double-click to complete the measurement.

Result List ​

Auto Calculate Protect Angle ​

Auto Calculate Protect Angle

Parameter ​

  • Profile Thickness(default value is "5.00m"): The width of the point cloud slice along the specified direction.
  • Filter Width(default value is "2.00m"): Point cloud filtering width.

Note: Please classify the tower points in advance.

Add point file.

Save the tower tilt file, the output file path will be displayed in log.

Delete the selected results list.

Clear the result list record.

Generate Report ​

Protect Angle

Parameters ​

Please refer to Report Parameters for details.